PeakHMI Drivers
- A/B DF1 (Redundant - Hot
Standby)
- PLC5, SLC500, SLC 5/01 -
5/05, MicroLogix
- A/B Ethernet (Redundant
- Hot Standby)
- ControlLogix,
CompactLogix, FlexLogix
- RSLinx not
required
- No third
party driver required
- A/B Ethernet PCCC (Redundant - Hot
Standby)
- SLC, MicroLogix, SLC 5/05,
PLC5
- RSLinx not
required
- No third
party driver required
- A/B Micro 8xx native TCP and serial
-
Bacnet/IP (Redundant
- Hot Standby)
- Analog Input, Analog Output, Analog Value, Binary
Input, Binary Output,
- Binary Value, Loop, Multi State Input, Multi State
Output, Averaging,
- Multi State Value, Life Safety Point, Life Safety
Zone
- Read Property, Write Property
- Delta computer systems - motion controllers - Delta
motion control protocol (DMCP)
- TCP/IP
and UDP/IP
- Read and write all files
and elements
- Collect plots using Method 2 - Advanced (No limit on plot size)
- DNP3
Master
- RS-232, RS-485 and TCP/IP
- DNP3 Outstation emulation
- Enron MODBUS
-
RTU over TCP/IP
- All register types
Fatek (Facon)
- RS-232/485, TCP/IP and UDP/IP
General purpose serial port
- Uses callbacks or polling scripts to control port
General purpose TCP/IP port
- Uses callbacks or polling scripts to control port
GE SNP-X (Redundant -
Hot Standby)
- All register types
- Long break or long
break free
GE SRTP (Redundant -
Hot Standby)
IDEC (OpenNet) (Redundant -
Hot Standby)
Keyence PLC (Redundant -
Hot Standby)
K-Sequence (Redundant -
Hot Standby)
- Automation Direct (DirectLogic,
Koyo)
- All register types
Master-K LS/LG
Industrial Systems (Redundant - Hot Standby)
Mewtocol-COM (Panasonic/Matsushita/Aromat/NAIS)
(Redundant - Hot Standby)
Mitsubishi FX 0,1,2,3
(Redundant - Hot Standby)
- Bit, Word, Longword, Float
Mitsubishi
Serial
(Redundant - Hot Standby)
- Protocol 3C, Format 1
or 4, Checksum or no checksum
- All register types
- Bit, Word, Longword, Float
Mitsubishi
TCP/IP
(Redundant - Hot Standby)
- Protocol 3E
- All register types
- Bit, Word, Longword, Float
- Protocol A 1E Frame, TCP/UDP, ASCII/Binary
Mitsubishi
TCP/IP, UDP/IP
- Protocol A, 1E Frame
- ASCII/Binary
- All register types
- Bit, Word, Longword, Float, String
MODBUS/J-Bus Serial
(RS-232/485) ASCII
- Master
- Bit, Float, String, Word
MODBUS/J-Bus Serial
(RS-232) RTU
(Redundant - Hot Standby)
- Master
and Slave
- Bit, Float, String, Word
MODBUS/J-Bus Serial
(RS-485) RTU
- Master
- Bit, Float, String, Word
MODBUS/J-Bus TCP/IP
(Redundant - Hot Standby)
- Master and Slave
- Bit, Float, String, Word
MQTT Client (Message Queuing Telemetry Transport)
- All QoS levels (Quality of Service)
- SSL supported (Secure Socket Layer)
ODBC (Open Database Connectivity)
- All dynamic tag values output to unlimited
number of concurrent databases
- Can be the source for analog or digital process
variables from unlimited number of concurrent databases
Omron
FINS (RS-232) (Redundant - Hot Standby)
- C, CV or
CS/CJ mode
- All register types
- Bit, Word, Longword, Float
Omron
FINS (TCP and UDP) (Redundant - Hot Standby)
- C, CV or
CS/CJ mode
- All register types
- Bit, Word, Longword, Float, String
Omron Hostlink/SYSMAC-WAY
(Redundant - Hot Standby)
- Bit, Word, Longword, Float
Omni
flow computers (Enron MODBUS) RS-232 and TCP
Saia-Burgess
- Serial-S-Bus (RS232/485)
- Ether-S-Bus
- Registers, Counters, Timers, Flags, Inputs, Outputs, Data blocks
- All data types -
bit, integer, float, string
Siemens S7-200 (PPI) (Redundant -
Hot Standby)
Siemens S7-200 (TCP/IP CP 243-1)
- Inputs, Outputs,
Analog Inputs, Analog Outputs, Variable memory, Timers, Counters,
Special memory
- All data types -
bit, byte, word, double word, float, timer, counter, string
Siemens S7-300/400 (MPI) (Redundant -
Hot Standby)
- Inputs, Outputs,
Internal memory, Timers, Counters
- All data types -
bit, byte, word, double word, float, timer, counter
Siemens S7-300/400/1200 (TCP) (Redundant -
Hot Standby)
- Inputs, Outputs,
Internal memory, Timers, Counters, Data blocks
- All data types -
bit, byte, word, double word, float, timer, counter
SNMP
(Simple Network Management Protocol) Version 1
- UDP
- Traps with logging
- GetRequest/SetRequest
Toshiba
ASCII computer link protocol
(RS-232/485)
- X, Y, R, S, T, C, D,
L registers
- Bit, Word, Longword, Float, String
Toshiba
ASCII computer link protocol
(UDP/IP)
- X, Y, R, S, T, C, D,
L registers
- Bit, Word, Longword, Float, String
Triconex Trident/Tri-GP
TSAA
(UDP/IP)
WeMo
-
Insight switch, Maker, Switch and Light switch
-
Uses subscriptions for reduced network loading